The Tulipa type T radiator comprises vertical flat-oval steel tubes of 57.5 x 10 x 1.5 mm and two horizontal round rear collectors Ø 35 x 2 mm, assembled with a regular centre 45 mm. The Tulipa type T with universal connection (1mm8) is available with valve set (optional) with 2 reducers 3/4”- 1/2” and a cover plate with curved base and in the color of the radiator.
The Tulipa is electrically welded by means of resistance welding robots, which gives the advantage of invisible weld-seams. For safety, the ends of the flat-oval tubes are rounded. The Tulipa is available with one row (type T1) or two rows of flat-oval tubes (type T2).
Moreover, it’s available as a space-divider in a free-standing installation or bowed with a minimum radius of 1.20 m (extra charge and a longer delivery time). The standard wall thickness of the flat-oval tubes is 1.5 mm and the standard service pressure is 4 bar (test pressure 6 bar). With a tube thickness of 2 mm the service pressure is 10 bar (test pressure 13 bar, with extra charge and longer delivery time). The maximum operating temperature is always 230°F (110°C). The Tulipa is available in different sizes from 19 1/2'' till 44 1/4'' width and the height from 15 3/4' till 118 1/8''. At a regime of 200/160/68°F the emission ranges from 1,354 BTU/hr till 33,245 BTU/hr.
To see the entire Vasco Tulipa product line, along with drawings and specs, CLICK HERE. Also see the Tulipa TSN product information.
|